NON-METALLIC FIBER OPTICAL CABLE FIGURE 8

GET FREE  AERIAL CAPB L(E FIG 8)

 

AESS-GESS 9/125 x 4~144C

Application:

– When the terrain is unsuitable for underground cable
– Where a permanent underground cable cannot be satisfactorily established
– Where short term provision for growth is necessary

1.         CABLE STRUCTURE

1.1:  Cross-sectional Drawing of Cable

 Table 1 – Diameter, Composition and Weight:

 

 No. of Fiber  

Nominal Cable Diameter

(mm)

 

Approx. Cable Weight

(kg/km)

 

Minimum Bending Radius

(mm)

 Under Load  No Load
31-60 9.8 133-136  196 98
61~72C 10.5 mm 183.17-187.68 210 105

 

  1. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TEST 

2.1. Mechanical and Environmental Performance of the Cable

 Table 2: The Mechanical and Environmental Performance of the Cable

 

ITEMS TEST METHOD AND ACCEPTANCE CRITERIA
Tenslide Strength # Test method: IEC 60794-1-2-E1

– Mandrel diameter: 30D (D = Cable Diameter)

– Max. tensile load: 500kg

– Continuously tensile load : 200kg

# Acceptance Criteria:

– Graph of fiber elongation (at maximum load) : £ 0.6%

– Attenuation increment: £ 0.1 dB

Compression Test # Test method: IEC 60794-1-2-E3

– Applied load: 1100 N/50 mm for 10 minutes

– No of points: 1

# Acceptance Criteria

– Attenuation Increment: £ 0.10 dB

– No jacket cracking and fiber breakage

Impact Resistance # Test method: IEC 60794-1–2E4

– Height of impact: 100 cm

– Drop hammer mass: 1 kg

– Radius impact surface : 25 mm

– No. of impact per point: 1

– No. of impact points: 10 points

# Acceptance Criteria

– Attenuation Increment  : £ 0.10 dB

– No jacket cracking and fiber breakage

Repeated Bending # Test method: IEC 60794-1-2-Method E11A

– Sheave diameter: 20D (D = cable diameter)

– Bend Angle : ± 90°

– No. of flexing cycles : 25 cycles

# Acceptance Criteria

– Attenuation Increment : £ 0.10 dB

– No jacket cracking and fiber breakage

Twisted Test # Test method: IEC 60794-1-2-E7

– Cable length twisted: 2m

– No. of twist cycles: 10 cycles

– Twist angle: ± 180°

# Acceptance Criteria

– Attenuation Increment: £ 0.10 dB after the completion of the test

– No jacket cracking and fiber breakage

 

Temperature Cycling # Test method: IEC 60794-1-2-F1

– Temperature cycling schedule  : 23°C ® -30°C ® +60°C ® 23°C

– Soak time at each temperature : 24 h

# Acceptance Criteria

– Attenuation increment: £ 0.1 dB/km

 

Water Penetration # Test method: IEC 60794-1-2-F5

– Length of specimen: 1m

– Height of pressure head: 1m

– Test time: 1h

# Acceptance Criteria

– No jacket cracking and fiber breakage

 

2.2  Phisical Performance of the Cable

Table 3: Phisical Performance of the Cable

 

 

ITEMS SPECIFICATION
Skin Type HDPE
Max. Electric field intensity £ 3.5kN
Max.Loading Capacity (Working) £ 2.5kN
Compression resitance 1500N/10cm
Temperature Elongation < 8.2×10-6/oC
Temprature range -5 oC ~ 70 oC
Humidity 1~100%
Min. Bend Radius before install ≥ 20 instalments diameter
Min. Bend Radius after install ≥ 10 instalments diameter