GET FREE  AERIAL CAPB L(E FIG 8)
 
AESS-GESS 9/125 x 4~144C

Application:

- When the terrain is unsuitable for underground cable
- Where a permanent underground cable cannot be satisfactorily established
- Where short term provision for growth is necessary

1.         CABLE STRUCTURE

1.1:  Cross-sectional Drawing of Cable


 Table 1 - Diameter, Composition and Weight:

 

 No. of Fiber

 

Nominal Cable Diameter

(mm)

 

Approx. Cable Weight

(kg/km)

 

Minimum Bending Radius

(mm)

 

 

 

 Under Load

 No Load

31-60

9.8 

133-136 

 196

98 

61~72C

10.5 mm

183.17-187.68

210

105

 

2.    PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TEST 

2.1. Mechanical and Environmental Performance of the Cable

 Table 2: The Mechanical and Environmental Performance of the Cable 

 

ITEMS

TEST METHOD AND ACCEPTANCE CRITERIA

Tenslide Strength

# Test method: IEC 60794-1-2-E1

- Mandrel diameter: 30D (D = Cable Diameter)

- Max. tensile load: 500kg

- Continuously tensile load : 200kg

# Acceptance Criteria:

- Graph of fiber elongation (at maximum load) : £ 0.6%

- Attenuation increment: £ 0.1 dB 

Compression Test

# Test method: IEC 60794-1-2-E3

- Applied load: 1100 N/50 mm for 10 minutes

- No of points: 1

# Acceptance Criteria

- Attenuation Increment: £ 0.10 dB

- No jacket cracking and fiber breakage

Impact Resistance

# Test method: IEC 60794-1--2E4

- Height of impact: 100 cm

- Drop hammer mass: 1 kg

- Radius impact surface : 25 mm

- No. of impact per point: 1

- No. of impact points: 10 points

# Acceptance Criteria

- Attenuation Increment  : £ 0.10 dB

- No jacket cracking and fiber breakage

Repeated Bending

# Test method: IEC 60794-1-2-Method E11A

- Sheave diameter: 20D (D = cable diameter)

- Bend Angle : ± 90°

- No. of flexing cycles : 25 cycles

# Acceptance Criteria

- Attenuation Increment : £ 0.10 dB

- No jacket cracking and fiber breakage

Twisted Test

# Test method: IEC 60794-1-2-E7

- Cable length twisted: 2m

- No. of twist cycles: 10 cycles

- Twist angle: ± 180°

# Acceptance Criteria

- Attenuation Increment: £ 0.10 dB after the completion of the test

- No jacket cracking and fiber breakage

 

Temperature Cycling

# Test method: IEC 60794-1-2-F1

- Temperature cycling schedule  : 23°C ® -30°C ® +60°C ® 23°C

- Soak time at each temperature : 24 h

# Acceptance Criteria

- Attenuation increment: £ 0.1 dB/km

 

Water Penetration

# Test method: IEC 60794-1-2-F5

- Length of specimen: 1m

- Height of pressure head: 1m

- Test time: 1h

# Acceptance Criteria

- No jacket cracking and fiber breakage

 

 

2.2  Phisical Performance of the Cable

Table 3: Phisical Performance of the Cable

 

 

ITEMS

SPECIFICATION

Skin Type

HDPE

Max. Electric field intensity

£ 3.5kN

Max.Loading Capacity (Working)

£ 2.5kN

Compression resitance

1500N/10cm

Temperature Elongation

< 8.2x10-6/oC

Temprature range

-5 oC ~ 70 oC

Humidity

1~100%

Min. Bend Radius before install

20 instalments diameter

Min. Bend Radius after install

10 instalments diameter