VINA-OFC Multi Funtion Optical Time Domain Reflectometer

This VINA-OFC series of OTDR is a multi-functional optical measuring instrument, 5,6 inch color screen, double operation of keys and touch. It integrates of OTDR, Visual Fault Location, Event map, Optical Power Meter, Light Source, Optical Loss Test, Optical End Face Detection multifunctions to help customers efficiently solve the field test and maintenance; Intelligent power management, 20 hours of super long standby, efficien guarantee of field test and maintenance

It is mainly used to measure the length, loss, connection quality and other parameters of all kind of optical fiber and cable. It can be widely used in engineering construction, emergency repair of communication system of optical fiber communication system, research and production measurement of firrst class optical fiber cable 

VO6000 Technical Specification

Model

VO6000 OTDR

 

S1

S2

S3

S4

T1

T2

T3

T4

T5

T6

F1

M1

SM1

SM2

 

Type

SM

MM

SM/MM

 

Wavelength

1310/

1550nm

1310nm

/1490nm

/1550nm

1310nm

/1550nm /1625nm

1310nm

/1550nm /1650nm

1310nm

/1490nm /1550nm /1625nm

850nm/

1300nm

850nm

/1300nm

/1310nm

/1550nm

 

Max

Dynamic Range

(dB)

35

/33

38

/36

42

/40

45

/43

32

/30

/30

37

/35

/35

32

/30

/30

37

/35

/35

32

/30

/30

37

/35

/35

37

/35

/35

/33

26

/28

26

/28

/35

/33

26

/28

/37

/35

 

Event Blind Zone

1m

0.8m

1m

 

ATT Blind zone

6m

6m

6m

 

Test Range

500m/1km/2km/4km/8km/16km/32km/64km/128km/256km

 

Pulse Width

3ns/5ns/10ns/30ns/50ns/80ns/160ns/320ns/500ns/800ns/1000ns/3000ns/5000ns/8000ns/10000ns/20000ns

 

Ranging accuracy

±0.75m+ Sample interval +0.005×Test distance

 

Loss accuracy

±0.05dB/dB

 

Sample Points

16k~256k

 

Sample Resolution

0.05m~16m

 

Reflection Accuracy

±3dB

 

File Format

SOR Standard File Format

 

Loss Analysis

4-point method /5-point method

 

Laser Safety Level

Class Ⅱ

 

Refresh Rate

3Hz (Typ.)

 

Data Storage

Internal storage100M≤3000 curves),Saleable to 4G or 8G (optional)External storage4G bit

 

Output Interface

FC/UPCInterchangeable SCST

 

Data Interface

USBMini-USB10M/100M Ethernet Port

 

 

 

Model

PON OTDR

 

PD1

PS1

PS2

PT1

PT2

PT3

PT4

Wavelength

1310nm±20nm1550nm±20nm

1625nm±20nm

(Filtered)

1650nm±5nm(Filtered)

1310nm/1550nm±20nm

1625nm±15nm (Filtered)

1310nm/1550nm±20nm

1650nm±5nm (Filtered)

Filter

/

High Pass >1595nm

Isolation>50dB(1270~1585nm)

Band pass 1650nm±7nm

Isolation>50dB

(1650nm±7nm)

High Pass

>1595nm,

Isolation>50dB

(1270nm~1585nm)

Band pass

1650nm±7nm,

Isolation>50dB

(1650nm±10nm)

Fiber type

G.652

 

Max Dynamic Range (dB)

37/35

38

38

38/36/36

40/38/38

42/40/40

38/36/36

Event Blind Zone

1m

0.8m

 

ATT Blind zone

6m

 

PON Blind zone

30m

 

Test Range

500m/1km/2km/4km/8km/16km/32km/64km/128km/256km

 

Pulse Width

3ns/5ns/10ns/30ns/50ns/80ns/160ns/320ns/500ns/800ns/1000ns/3000ns/5000ns/8000ns/10000ns/20000ns

 

Range Accuracy

±0.75m+ Sample interval +0.005×Test distance

 

Loss Resolution

±0.001dB

 

Loss Accuracy

±0.05dB/dB

 

Sample Points

16k~256k

 

Sample Resolution

0.05m~16m

 

Reflection Accuracy

±3dB

 

File Format

SOR Standard File Format

 

Loss Measurement Mode

4-point method /5-point method

 

Laser Safety Level

Class Ⅱ

 

Refresh Rate

3Hz (Typ.)

 

Data Storage

Internal storage100M≤3000 curves);External storage4G bit

 

Connector

FC/UPCInterchangeable SCST

 

Data Interface

USBMini-USB10M/100M Ethernet Port

 

OPM

 

Wavelength range

800nm~1700nm

 

Connector

Universal FC/SC/ST

 

Test scope

-50dBm+26dBm

 

Uncertainty

±5%

 

Calibration wave

850nm/980nm/1300nm/1310nm/1490nm/1550nm/1625nm/1650nm

 

LS

 

Wavelength

Consistent with OTDR output wavelength

 

Laser Type

FP-LD

 

Connector

FC/UPCInterchangeable SCST

 

Output power

≥-5dBm

 

Stability

CW±0.5dB/15minTest after 15 minutes of boot-up preheating

 

VFL

 

Wavelength

650nm±20nm

 

Output power

≥10mW

 

Mode

CW/1Hz/2Hz

 

Connector

FC/UPCInterchangeable SCST

 

The Optical Loss Test index refers to the above light source and optical power meter index.

 

Others

 

Display

5.6 inch color LCD + touch screen

 

Power supply

AC/DC adapterInput100V240V50/60Hz0.6AOutput12V~19V1.5A; Lithium battery7.4V5200mAh (Max. 20 hours working time)

 

Working temperature

-10℃+50℃

 

Storage temperature

-40℃+70℃

 

Relative humidity

095%,Non Condensing

 

Weight

≤1.2kg

 

Size

227mm×160mm×70mm